{
  "schema_version": "1.0",
  "model_id": "PL2025_METHOD_CLOSURE_CANDIDATE",
  "package_version": "2026-10-20.1",
  "variant": "source_energy",
  "title_pl": "Polska 2025 — projekt modelu energii do konsultacji, 20.10.2026",
  "author": "Multicert Sp. z o.o.",
  "country": "PL",
  "reference_year": 2025,
  "functional_unit": {
    "quantity": 1,
    "unit": "kWh",
    "description_pl": "1 kWh energii elektrycznej fizycznie dostarczonej odbiorcy w Polsce; średnia roczna 2025 przy krajowej strukturze napięć."
  },
  "electricity_mix_type": "physical_national",
  "voltage_scope": "national_aggregate_not_voltage_specific",
  "is_default": false,
  "status": {
    "state": "consultation_candidate",
    "label_pl": "Projekt do konsultacji",
    "computation_complete": true,
    "internal_technical_review_completed": true,
    "human_verification_recorded": false,
    "external_expert_review": "NOT_PERFORMED",
    "internal_checks_are_external_expert_review": false,
    "production_approved": false,
    "formal_EN15804_qualification": false,
    "operator_decision_signed": false,
    "description_pl": "Obliczenia i kontrola techniczna zakończone. Projekt udostępniony do uwag; niezależny przegląd ekspercki i przyjęcie do zastosowania pozostają odrębnymi etapami."
  },
  "intended_use": "technical_consultation_and_method_review",
  "method": {
    "documentation": "METODA-I-ZMIANY.txt",
    "allocation": "aE = E / (E + qQ), q = 0.35",
    "description_pl": "Wspólny podział nowych strumieni węgla kamiennego i brunatnego na prąd oraz ciepło, jawny rachunek węgla biogenicznego i regionalizacja zidentyfikowanej krajowej wody kopalnianej."
  },
  "restrictions_pl": [
    "Projekt do oceny metody i danych. Samo opublikowanie projektu nie oznacza przyjęcia go do wydawanych deklaracji środowiskowych wyrobów.",
    "Wyniki opisują wkład energii, nie cały wyrób lub pełny etap jego cyklu życia.",
    "Fizyczny miks krajowy nie jest miksem dostawcy, kontraktowym ani resztkowym; nie jest profilem konkretnego napięcia.",
    "Rok odniesienia 2025 nie oznacza aktualizacji wszystkich historycznych procesów tła do 2025 r.",
    "Analizy wrażliwości są wariantami założeń, nie przedziałami ufności."
  ],
  "limitations_pl": [
    "q = 0,35 to przybliżenie jakości ciepła. Nieodtworzone historyczne wymiany pozostają w dotychczasowych ilościach na kWh.",
    "Rachunek biogeniczny obejmuje wskazane transfery; nie jest pełnym fizycznym bilansem całej bazy. Brak współczynników dla biogenicznego CO i olejów pozostaje ujawnionym ograniczeniem.",
    "Właściwości gazu oraz ilość drewna kopalnianego oparto częściowo na historycznych danych i oszacowaniach.",
    "Pobór wody kopalnianej i zwrot 90% to założenia źródłowe, nie pomiary z 2025 r.",
    "Ocena jakości 73 decyzji nie oznacza wysokiej jakości danych; istotne tło pozostaje historyczne lub zastępcze."
  ],
  "source_attribution": "Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026",
  "terms_url": "WARUNKI-WYKORZYSTANIA.txt",
  "licensing": {
    "upstream_terms_url": "https://nexus.openlca.org/ws/files/40247",
    "source_data_modified": true,
    "source_provider_endorsement_claimed": false,
    "unrestricted_database_redistribution_granted": false
  },
  "provenance": {
    "calculation_date": "2026-10-20",
    "source_result_sha256": "979557fae0d52a9c949b2c9d536bdd1eb1ce4baac40017e192edadcd91224a14",
    "source_csv_sha256": "f7c6f7440b946ae600a86d4c3c43f6db7a99aaa1ac597e1c546d765654e04a7e",
    "technical_acceptance_sha256": "ff9bd732de85b04a140f98f1ac657226a994143ff2a00dcc4068697a6ad210e3",
    "previous_public_profile": "/data/energia-pl-2025-v4/profil-37.json",
    "previous_profile_is_replaced": false
  },
  "indicators": [
    {
      "code": "GWP-total",
      "name_pl": "Potencjał globalnego ocieplenia — łącznie",
      "value_per_kWh": 0.6472750830697663,
      "impact_unit": "kg CO2 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "GWP-fossil",
      "name_pl": "Potencjał globalnego ocieplenia — pochodzenie kopalne",
      "value_per_kWh": 0.645814991576697,
      "impact_unit": "kg CO2 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "GWP-biogenic",
      "name_pl": "Potencjał globalnego ocieplenia — pochodzenie biogeniczne",
      "value_per_kWh": 0.0013457094218741437,
      "impact_unit": "kg CO2 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "GWP-luluc",
      "name_pl": "Potencjał globalnego ocieplenia — użytkowanie gruntów i jego zmiany",
      "value_per_kWh": 0.00011438207119520214,
      "impact_unit": "kg CO2 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "ODP",
      "name_pl": "Potencjał zubożenia warstwy ozonowej",
      "value_per_kWh": 4.010742490247474e-09,
      "impact_unit": "kg CFC11 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "AP",
      "name_pl": "Potencjał zakwaszenia",
      "value_per_kWh": 0.0010846349344005874,
      "impact_unit": "mol H+ eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "EP-fw",
      "name_pl": "Potencjał eutrofizacji wód słodkich",
      "value_per_kWh": 6.266590352641346e-05,
      "impact_unit": "kg P eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "EP-mar",
      "name_pl": "Potencjał eutrofizacji morskiej",
      "value_per_kWh": 0.00021979173206415075,
      "impact_unit": "kg N eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "EP-ter",
      "name_pl": "Potencjał eutrofizacji lądowej",
      "value_per_kWh": 0.0024557932079604765,
      "impact_unit": "mol N eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "POCP",
      "name_pl": "Potencjał powstawania ozonu przygruntowego",
      "value_per_kWh": 0.0007625694329655857,
      "impact_unit": "kg NMVOC eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "ADP-mm",
      "name_pl": "Potencjał wyczerpywania zasobów abiotycznych — minerały i metale",
      "value_per_kWh": 7.900974421117845e-07,
      "impact_unit": "kg Sb eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "ADP-fossil",
      "name_pl": "Potencjał wyczerpywania zasobów abiotycznych — paliwa kopalne",
      "value_per_kWh": 7.203216957632466,
      "impact_unit": "MJ (net calorific)",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "WDP",
      "name_pl": "Potencjał pozbawienia wody",
      "value_per_kWh": 0.017305608868286276,
      "impact_unit": "m3 world eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PM",
      "name_pl": "Potencjalna zachorowalność związana z pyłem",
      "value_per_kWh": 4.735631869688809e-09,
      "impact_unit": "disease incidence",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "IRP",
      "name_pl": "Potencjalny wpływ promieniowania jonizującego na zdrowie",
      "value_per_kWh": 0.006816918041380697,
      "impact_unit": "kBq U235 eq",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "ETP-fw",
      "name_pl": "Potencjał ekotoksyczności wód słodkich",
      "value_per_kWh": 1.9766588997572172,
      "impact_unit": "CTUe",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "HTP-c",
      "name_pl": "Potencjał toksyczności dla ludzi — skutki rakotwórcze",
      "value_per_kWh": 3.234739595945085e-10,
      "impact_unit": "CTUh",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "HTP-nc",
      "name_pl": "Potencjał toksyczności dla ludzi — skutki inne niż rakotwórcze",
      "value_per_kWh": 7.826023966783144e-09,
      "impact_unit": "CTUh",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "SQP",
      "name_pl": "Potencjalny wpływ użytkowania gruntów na jakość gleby",
      "value_per_kWh": 3.278394853087632,
      "impact_unit": "dimensionless (pt)",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PERE",
      "name_pl": "Odnawialna energia pierwotna z wyłączeniem zasobów użytych jako surowce",
      "value_per_kWh": 1.92673527617644,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PERM",
      "name_pl": "Odnawialne zasoby energii pierwotnej użyte jako surowce",
      "value_per_kWh": 0.0,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PERT",
      "name_pl": "Całkowite wykorzystanie odnawialnych zasobów energii pierwotnej",
      "value_per_kWh": 1.9267352761764398,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PENRE",
      "name_pl": "Nieodnawialna energia pierwotna z wyłączeniem zasobów użytych jako surowce",
      "value_per_kWh": 7.220855675787145,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PENRM",
      "name_pl": "Nieodnawialne zasoby energii pierwotnej użyte jako surowce",
      "value_per_kWh": 0.0,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "PENRT",
      "name_pl": "Całkowite wykorzystanie nieodnawialnych zasobów energii pierwotnej",
      "value_per_kWh": 7.220855675787146,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "SM",
      "name_pl": "Wykorzystanie materiałów wtórnych",
      "value_per_kWh": 0.001964688203361935,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "RSF",
      "name_pl": "Wykorzystanie odnawialnych paliw wtórnych",
      "value_per_kWh": 0.002610644970605357,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "NRSF",
      "name_pl": "Wykorzystanie nieodnawialnych paliw wtórnych",
      "value_per_kWh": 0.0,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "FW",
      "name_pl": "Zużycie netto zasobów wody słodkiej",
      "value_per_kWh": 0.002047234914827837,
      "impact_unit": "m3",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "HWD",
      "name_pl": "Odpady niebezpieczne poddane unieszkodliwianiu",
      "value_per_kWh": 0.11522455161706043,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "NHWD",
      "name_pl": "Odpady inne niż niebezpieczne poddane unieszkodliwianiu",
      "value_per_kWh": 1.8556866735697828,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "RWD",
      "name_pl": "Odpady promieniotwórcze poddane unieszkodliwianiu",
      "value_per_kWh": 0.0002928885274595877,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "CRU",
      "name_pl": "Komponenty przeznaczone do ponownego użycia",
      "value_per_kWh": 0.0,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "MFR",
      "name_pl": "Materiały przeznaczone do recyklingu",
      "value_per_kWh": 9.651018612809654e-06,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "MER",
      "name_pl": "Materiały przeznaczone do odzysku energii",
      "value_per_kWh": 0.0,
      "impact_unit": "kg",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "EEE",
      "name_pl": "Eksportowana energia elektryczna",
      "value_per_kWh": 0.0010206984004328048,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    },
    {
      "code": "EET",
      "name_pl": "Eksportowana energia cieplna",
      "value_per_kWh": 0.004668827944946297,
      "impact_unit": "MJ",
      "denominator_unit": "kWh",
      "value_status": "calculated_under_declared_proxies"
    }
  ]
}
